| CV100-4T-0075G |
7.5 |
3-phase 0~rated input voltage |
17.0 |
150% 1 Minute; 180% 10 Seconds; 10 minutes interval(inverse time limit speciality) |
3-phase 380V~440V AC; 50Hz/60Hz |
320V~460V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% |
20.5 |
Built-in |
Cooling by fan |
| CV100-4T-0055G |
5.5 |
3-phase 0~rated input voltage |
13.0 |
150% 1 Minute; 180% 10 Seconds; 10 minutes interval(inverse time limit speciality) |
3-phase 380V~440V AC; 50Hz/60Hz |
320V~460V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% |
14.5 |
Built-in |
Cooling by fan |
| CV100-4T-0037G |
3.7 |
3-phase 0~rated input voltage |
8.8 |
150% 1 Minute; 180% 10 Seconds; 10 minutes interval(inverse time limit speciality) |
3-phase 380V~440V AC; 50Hz/60Hz |
320V~460V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% |
10.5 |
Built-in |
Cooling by fan |
| CV100-4T-0022G |
2.2 |
3-phase 0~rated input voltage |
5.5 |
150% 1 Minute; 180% 10 Seconds; 10 minutes interval(inverse time limit speciality) |
3-phase 380V~440V AC; 50Hz/60Hz |
320V~460V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% |
5.8 |
Built-in |
Cooling by fan |
| CV100-4T-0015G |
1.5 |
3-phase 0~rated input voltage |
3.7 |
150% 1 Minute; 180% 10 Seconds; 10 minutes interval(inverse time limit speciality) |
3-phase 380V~440V AC; 50Hz/60Hz |
320V~460V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% |
5.0 |
Built-in |
Cooling by fan |
| CV100-4T-0007G |
0.75 |
3-phase 0~rated input voltage |
2.3 |
150% 1 Minute; 180% 10 Seconds; 10 minutes interval(inverse time limit speciality) |
3-phase 380V~440V AC; 50Hz/60Hz |
320V~460V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% |
3.4 |
Built-in |
Cooling by fan |
| CV100-2S-0022G |
2.2 |
3-phase 0~rated input voltage |
10.0 |
150% 1 Minute; 180% 10 Seconds; 10 minutes interval(inverse time limit speciality) |
single phase 200V~240V AC; 50Hz/60Hz |
180V~260V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% |
23.0 |
Built-in |
Cooling by fan |
| CV100-2S-0015G |
1.5 |
3-phase 0~rated input voltage |
7.5 |
150% 1 Minute; 180% 10 Seconds; 10 minutes interval(inverse time limit speciality) |
single phase 200V~240V AC; 50Hz/60Hz |
180V~260V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% |
14.0 |
Built-in |
Cooling by fan |
| CV100-2S-0007G |
0.75 |
3-phase 0~rated input voltage |
4.0 |
150% 1 Minute; 180% 10 Seconds; 10 minutes interval(inverse time limit speciality) |
single phase 200V~240V AC; 50Hz/60Hz |
180V~260V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% |
8.2 |
Built-in |
Cooling by fan |
| CV100-2S-0004G |
0.4 |
3-phase 0~rated input voltage |
2.5 |
150% 1 Minute; 180% 10 Seconds; 10 minutes interval(inverse time limit speciality) |
single phase 200V~240V AC; 50Hz/60Hz |
180V~260V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% |
5.3 |
Built-in |
Cooling by fan |
| CV100-2S-0002G |
0.2 |
3-phase 0~rated input voltage |
1.3 |
150% 1 Minute; 180% 10 Seconds; 10 minutes interval(inverse time limit speciality) |
single phase 200V~240V AC; 50Hz/60Hz |
180V~260V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% |
2.3 |
Built-in |
Cooling by fan |